Anchor Points for Fall Protection: What You Need to Know

Managing Director
Lucian Ivan
• 15 minute read
Contents
- What Are Anchor Points?
- Anchorage: Anchor Point, Anchor Device or Anchor System?
- Types of Anchors
- Single-User vs. Multi-User Anchors
- Anchor Regulations and Standards
- How to Maintain Your Anchor System
- Is Your Anchor System Safe and Compliant?
Falls from height are the leading cause of workplace fatalities in the UK, accounting for more than a third of all fatal injuries in 2023/24, according to the Health and Safety Executive (HSE).
Central to preventing such tragedies are anchor points – secure attachment points for fall protection equipment like harnesses and lifelines. Proper understanding and implementation of these systems are vital for safeguarding workers at height.
In this guide, we’ll break down everything you need to know about anchor points for fall protection. We’ll clarify the difference between anchor points, anchor devices, and anchor systems, explore the common types of anchors used in fall protection, and outline the essential regulations you need to follow to ensure safety and compliance.
Whether you're a facilities manager, property manager or compliance officer, this article will help you make informed decisions about your anchor systems and keep workers safe.
What Are Anchor Points?
An anchor point is a secure location on an anchor system where a worker's personal fall protection equipment (PFPE) – such as a harness, lanyard or self-retracting lifeline – is attached. It is designed to withstand forces generated in fall arrest, fall restraint or work positioning systems, depending on its intended use and certification.

Anchor points are part of a broader anchorage system, which includes the anchor device and any structural components needed to ensure proper load distribution. When correctly selected and installed, they form a critical part of an engineered system to either prevent a fall (fall restraint), arrest a fall in progress (fall arrest), or support a worker in a stable position while working at height (work positioning).
In everyday language, the term ‘anchor point’ is often used more broadly, with many people referring to anchor devices or complete anchorage systems as "anchor points". In fact, these systems include multiple components beyond just the attachment point. In the next section, we’ll break down the key differences between anchor points, anchor devices, and anchor systems
Anchorage: Anchor Point, Anchor Device or Anchor System?
The term “anchor point” is often used as a catch-all phrase for an entire anchorage system. However, industry standards like BS 7883 and BS EN 795 define anchor points, anchor devices and anchor systems as distinct concepts, each playing a specific role in ensuring worker safety.
Here’s a quick breakdown of how these terms are defined:
Anchor Point
As already covered, an anchor point is a specific location on an anchorage system where personal fall protection equipment (PFPE) – such as a lanyard or lifeline – is attached. It can be fixed or mobile, depending on whether it allows a worker to move along a guided track.
Anchor Device
An anchor device is a broader assembly that includes one or more anchor points and the components that facilitate attachment to a structure.
The designated standards categorise anchor devices into five basic types:
-
Type A: Fixed anchors requiring structural fixing (e.g. eyebolts).
-
Type B: Transportable, non-fixed anchors (e.g. beam clamps, slings, tripods).
-
Type C: Flexible horizontal lifelines (e.g. roof-top cable systems).
-
Type D: Rigid horizontal anchor systems (e.g. fixed rail systems).
-
Type E: Mass and friction-based anchors (e.g. deadweight anchors).
These classifications ensure that anchor devices are installed and used correctly based on the working environment and structural requirements. We’ll take a look at anchor types in more depth later in this article.
Anchor System
An anchor system refers to the complete setup that incorporates an anchor device (with anchor points) and its connection to the structure. This includes elements like the structural anchor, base material, and any required fixing components.
While BS 7883 provides guidance on the selection and installation of anchor systems, BS 8610 outlines the type testing requirements for anchor systems, ensuring they meet safety and performance standards.
Why Does It Matter?
Although it’s generally not critical in everyday conversation, it is important to understand the differences between these terms. Using the term “anchor point” incorrectly can lead to miscommunication, improper system selection or non-compliance with safety standards.
For example, someone might refer to “an anchor point on the roof” when they are actually describing a horizontal lifeline system, which contains multiple anchor points and requires different installation and inspection criteria.
By clearly distinguishing between anchor points, anchor devices and anchor systems, you can ensure the correct selection, installation and use of fall protection equipment, keeping workers safe and meeting the correct regulatory requirements.
Types of Anchors
There are many types of anchors used in fall protection, each designed for specific environments and applications. While this article focuses on some of the most common variants, the full range of anchor systems extends well beyond what we cover here.
Anchor types are categorised under BS 7883 and BS EN 795, which outline their design, installation and performance requirements. Below, we break down the primary classifications and some of their most common subtypes.
Fixed Anchors (BS EN 795 - Type A)
Fixed anchors provide a permanent attachment point for fall protection systems. These anchors require structural fixing and must be installed on suitable load-bearing materials such as concrete, steel, or brick.

-
Eyebolts: A single fixed anchor point, very commonly used for fall restraint, fall arrest, work positioning and rope access systems.
-
Fixed posts: A vertical post secured to a structure, commonly used on rooftops.
-
Base plates: Flat metal plates bolted to a structure, offering a secure anchor point for PFPE.
Temporary Anchors (BS EN 795 - Type B)
Temporary anchors are non-permanent and designed for easy removal and transport. They do not require structural fixing, making them ideal for short-term work at height.

-
Tripods: Freestanding anchors typically used for confined space entry, often combined with a winch system.
-
Davits: Portable, rotating arms, often used for rescue or suspended access, especially when working in confined spaces.
-
Beam anchors: Adjustable anchors that clamp onto steel beams, providing a secure attachment point for workers.
-
Slings: Flexible straps that wrap around beams, columns or other structures to create a temporary anchor point.
Horizontal Lifelines (BS EN 795 - Type C & D)
Horizontal lifeline systems allow workers to move laterally while remaining secured. These systems can be flexible (cable-based) or rigid (rail-based).

-
Flexible (BS EN 795 - Type C): A cable-based system (e.g., stainless steel wire rope) that provides continuous attachment while allowing movement along the line. Often installed on rooftops or large structures.
-
Rigid (BS EN 795 - Type D): A fixed rail system that provides a secure track for a traveller device. Used in similar circumstances to flexible systems.
Horizontal lifelines are also frequently referred to as “mansafe systems”, which originated as a popular brand name. You can learn more about mansafe systems here.
Vertical Lifelines (BS EN 353-1 & BS EN 353-2)
Vertical lifelines provide fall protection for workers climbing ladders, towers, or tall structures. These systems allow movement while ensuring immediate fall arrest if the user loses grip.

-
Rigid (BS EN 353-1): A fixed rail system with a sliding traveller that locks in the event of a fall. Often used on telecom masts and wind turbines.
-
Flexible (BS EN 353-2): A rope or cable-based system with a guided fall arrestor, offering similar protection but with greater adaptability for various structures.
Mass & Friction Anchors (BS EN 795 - Type E)
Mass and friction anchors rely on weight and surface friction rather than structural fixing. These anchors are only suitable for flat roofs or temporary work areas where drilling into the structure is not an option.

Their effectiveness depends on factors like surface conditions, weight distribution, and environmental factors – wet or slippery surfaces, contaminants, or incorrect positioning can significantly reduce their stability.
-
Counterweights: Weighted anchor systems designed for use on rooftops, using mass to resist fall forces.
-
Vacuum anchors: Suction-based anchors that create a strong, temporary attachment on smooth surfaces like glass or metal.
The right anchor depends on many factors, from structural compatibility to manufacturer guidelines. If you need support to select the correct option, reach out to our fall protection experts for guidance tailored to your circumstances.
Single-User vs. Multi-User Anchors
When selecting an anchor system, one of the most important considerations is how many people will be attached at once. Anchor devices and systems are designed, tested, and certified for either single-user or multi-user applications, with strict regulations governing their use.
Single-User Anchors
Single-user anchors are designed to support the load of just one person at a time. These systems are tested to ensure they can withstand the forces generated by an individual fall without failure.
In alignment with BS EN 795:2012, most anchor devices are only rated for single-user use unless explicitly tested and certified for multiple users.
Common single-user anchors include:
-
Fixed eyebolts: One of the most common anchor devices, most frequently certified for single-user applications.
-
Temporary slings or beam clamps: Used in maintenance or construction environments.
-
Personal deadweight anchors: Often used where structural fixing isn’t possible.
Using a single-user anchor for multiple workers greatly increases the risk of failure, as it has not been tested to handle the combined forces of multiple simultaneous falls.
Multi-User Anchors
Multi-user anchor systems are designed to withstand the forces generated by multiple attached users. These systems must comply with PD CEN/TS 16415:2013, which outlines additional testing and safety requirements for anchor devices supporting more than one person.
Examples of multi-user anchor systems include:
-
Horizontal lifeline systems (multi-user depending on the system): Often designed for multiple users moving along a flexible or rigid track.
-
Engineered overhead rails: Found in industrial and transport settings, allowing several users to connect at once.
-
Heavy-duty davit arms or tripods: Used for confined space entry and rescue operations.
To comply with PD CEN/TS 16415, multi-user anchors must be tested to handle the additional dynamic forces created by simultaneous falls. The design must also prevent excessive loading on any single component and ensure safe clearances for each attached worker.
What to Consider for Anchor Selection
When choosing between single-user and multi-user anchors, consider:
-
Load ratings: Ensure the anchor is tested and certified for the required number of users.
-
Separation distances: Workers using the same anchor system must have enough clearance to avoid collision during a fall.
-
System compatibility: Some PFPE is designed only for single-user applications, even if the anchor itself is rated for multi-user use.
-
Inspection and maintenance: Multi-user anchors may require more frequent inspection and higher maintenance standards to remain compliant.
Why Does It Matter?
The wrong anchor system can lead to overloading, system failure, and serious injury or death. Misuse of a single-user anchor for multiple workers is a common compliance breach that can result in legal consequences under The Work at Height Regulations 2005.
We strongly recommend that all anchor points and systems meet the correct BS, EN, and CEN/TS standards and are used accordingly.
Anchor Regulations and Standards
Fall protection anchor systems must comply with strict safety regulations and standards to ensure worker protection and legal compliance. These requirements cover everything from minimum strength ratings to installation, inspection and certification.
Before we cover the specific legislation and standards, here’s a quick summary of some of the core requirements:
-
Minimum strength: Anchors must meet load-bearing requirements as specified by the relevant standards and manufacturer recommendations.
-
Certification and compliance: Anchor systems must be tested and certified according to the applicable BS, EN, and CEN/TS standards.
-
Location and suitability: The chosen anchor must be structurally sound, installed in a suitable material, and positioned to minimise fall risks.
-
Installation: Permanent anchors must be installed by competent persons following the manufacturer’s instructions and relevant standards.
-
Inspection and testing: Regular inspection, testing, and recertification are required, with periodic checks typically every 6-12 months, or more frequently for heavily used systems.
While this is not an exhaustive list, the standards below represent some of the most relevant legislation and guidance for anchor systems in the UK.
The Work at Height Regulations 2005
This is the primary legal framework for fall protection in the UK. It places a legal duty on employers and building owners to ensure that work at height is properly planned, supervised, and carried out safely.
Key points:
-
Employers must eliminate or minimise risks from working at height.
-
Fall protection systems, including anchors, must be suitable, inspected and maintained.
-
Workers must be trained and competent in using fall protection equipment.
BS EN 795 – Personal Fall Protection Equipment: Anchor Devices
BS EN 795:2012 sets out performance, design and testing requirements for anchor devices used in personal fall protection systems.
Key points:
-
It categorises anchor devices into Types A-E, defining their design and installation criteria.
-
It applies primarily to removable anchor devices and does not cover structural anchors (which are covered by BS 7883).
-
PD CEN/TS 16415 extends this standard to cover multi-user anchor devices.
BS 7883 – Anchor System Design, Installation and Inspection
BS 7883:2019 provides guidance on the design, selection, installation and inspection of anchor systems, particularly those permanently fixed to structures. This latest version supersedes BS 7883:2005, including many important updates, like the expansion of scope to cover the five types of anchor systems described within BS EN 795.
Key points:
-
Covers testing, inspection and re-certification of anchor systems – now including pre-use, periodic, interim, and supplementary inspections, with clearer pass/fail categories.
-
Addresses load distribution, fixing methods and compatibility with PFPE.
-
Introduces the “system designer” role – a competent person responsible for the overall design of the personal fall protection system (PFPS) including the anchor system, considering structural integrity, user needs, certification, and handover documentation
-
Requires a system technical file – a crucial record of design, installation and inspections given to the duty holder for compliance and safety tracking throughout the system's life.
BS 8610 – Type Testing of Anchor Systems
This standard covers type testing of complete anchor systems, ensuring they meet performance and durability criteria.
Key points:
-
Covers both anchor devices and their structural anchors.
-
Ensures systems withstand real-world fall forces.
-
Provides criteria for deformation testing, corrosion resistance and environmental durability.
BS EN 353-1 & BS EN 353-2 – Vertical Lifeline Systems
These standards cover vertical anchor systems that protect workers climbing ladders, towers or other structures.
Key points:
-
BS EN 353-1 applies to rigid vertical lifelines (rails).
-
BS EN 353-2 applies to flexible vertical lifelines (cables or ropes).
-
Both define testing, strength and performance criteria for fall arresters attached to vertical lifelines.
PD CEN/TS 16415 – Multi-User Anchor Devices
This technical specification extends BS EN 795 to cover anchor devices used by more than one person at a time.
Key points:
-
Ensures multi-user anchors can withstand higher fall forces.
-
Requires additional strength testing and risk mitigation.
-
A critical requirement for workplaces where multiple workers use the same system.
How to Maintain Your Anchor System
Regular maintenance for your anchor system is essential to ensure worker safety, regulatory compliance, and the long-term reliability of your fall protection system.
Over time, regular use, environmental exposure or unseen structural issues can compromise the integrity of anchor devices. Without regular inspections, an anchor system may not function as expected in a fall event, putting lives at risk.

BS 7883:2019 provides detailed guidance on maintenance requirements, including inspection schedules, record-keeping and other conditions of compliance.
This section will give you a brief overview of what's required to keep your anchor system in good working order.
What Are the Main Inspection Requirements?
Anchor systems must be inspected at regular intervals to identify wear, corrosion or damage. BS 7883:2019 outlines four key types of inspection:
- Pre-use checks: Quick visual and tactile checks before each use to spot obvious damage or defects. Users must be trained to conduct these properly.
- Periodic inspections: Comprehensive examinations by a competent person, typically every 6-12 months (though you must validate this period for your system). For systems or components under LOLER, these are also known as Thorough Examinations.
- Interim inspections: Additional checks triggered by specific events, such as a fall, severe weather, or exposure to corrosive environments.
- Supplementary inspections: Required for hidden structural components, such as anchors embedded beneath roofing materials, often guided by original installation records.
Failure to inspect and maintain an anchor system in-line with standards can lead to serious compliance breaches under UK safety law.
Your Responsibilities as a Duty Holder
In simple terms, the Duty Holder is the person or organisation ultimately responsible for the safety and upkeep of fall protection anchor systems, as indicated by BS 7883:2019.
In general, the Duty Holder is either a person or company that has been formally assigned responsibility for the system's safety (e.g. a health and safety manager or facilities manager), or the landlord or building owner.
If you are the Duty Holder, you are legally responsible for ensuring that your fall protection systems remain safe and compliant. Some key responsibilities include:
-
Ensuring inspections are carried out by a competent person at the correct intervals.
-
Maintaining a system technical file, which includes design specifications, installation details, and the examination scheme.
-
Keeping an up-to-date Operation & Maintenance (O&M) manual available for users.
-
Removing defective systems from service immediately and arranging for remedial work.
-
Training workers on how to conduct pre-use checks and safely use the system.
-
Ensuring Personal Fall Protection Equipment (PFPE) used with the anchor system is also regularly inspected and maintained according to BS 8437.
By following the maintenance framework outlined in BS 7883:2019, you can reduce fall risks, meet legal obligations, and create a safer working environment.
If you’re unsure whether your anchor system meets the latest standards, professional inspection and testing can help. Our team provides complete installation, testing and certification services, ensuring your system remains fully compliant and fit for purpose.
Is Your Anchor System Safe and Compliant?
Anchor systems are a critical line of defence against falls from height, but without proper installation, testing, and maintenance, they can fail when you need them most.
Ensuring your system meets BS 7883:2019 and other key safety standards isn’t just about compliance – it’s about protecting lives.
At Spectrum, we provide:
-
✅ Specialist Design & Installation: We tailor anchor systems to your building, ensuring optimal safety, durability, and compliance from day one.
-
✅ Thorough Inspections & Compliance Audits: We conduct detailed safety inspections and certifications, identifying hidden risks and keeping you compliant with BS EN 795, BS 7883, PD CEN/TS 16415, and more.
-
✅ Proactive Maintenance: We provide scheduled testing and maintenance, helping to identify faults before they become safety risks.
Don’t take risks with fall protection. Learn more about our service here or book an inspection today and make sure your anchor system is fully compliant, reliable, and fit for purpose.
Your Building Deserves Thoughtful, Expert Care
Ensure your building remains in top condition with Spectrum Specialist Support. Our expert team offers a full range of exterior maintenance services, from external cleaning and repairs to comprehensive restoration of brick, render, stone and other substrates.
With an IRATA-certified team of abseilers and experience across hundreds of varied projects, we’ll find an access solution that saves you time and money, even on the most complex elevations.
Whether you need emergency maintenance or a tailored service plan, we are here to help. Contact us directly on 020 3551 6206 or email us at info@spectrumss.co.uk to discuss your requirements and receive a free consultation and quote.