Temporary Anchors: The Basics of Portable Fall Protection

Managing Director
Lucian Ivan
• 8 minute read
Contents
- What Are Temporary Anchors?
- Why Use Temporary Anchors?
- Types of Temporary Anchor Systems
- Regulations and Strength Requirements
- How to Choose the Right Temporary Anchor
- Installation and Best Practices
- Inspection and Maintenance
- Common Mistakes to Avoid
- Need Help Choosing or Installing Temporary Anchors?
Working at height is one of the most dangerous activities in the UK construction and maintenance sectors. Whether you're inspecting a facade, cleaning windows, or conducting roof repairs, having a secure anchor point is critical. But not every job justifies permanent anchors. This is where temporary anchor systems can be especially useful.
In this guide, we'll break down what temporary anchors are, the different types available, how to choose the right one, and what regulations you need to comply with. Whether you're a facilities manager, surveyor, or compliance officer, this article is your go-to reference for using temporary anchors safely and effectively.
Note: This article provides general guidance at the time of writing and is not a substitute for legal or professional advice. Requirements can change, and the right approach will depend on your building, site conditions and the work involved. Always consult a suitably qualified professional or contact our team for tailored advice.
What Are Temporary Anchors?
Temporary anchors are fall protection devices that provide a secure attachment point for workers performing tasks at height, without requiring permanent installation into the structure. They’re typically used for short-term or one-off jobs and are removed after the work is completed.
There are two main categories:
-
Installed Anchors: Temporarily fixed into a structure (e.g., through bolts).
-
Placed Anchors: Positioned without structural penetration (e.g., deadweight anchors).
They're widely used across construction, maintenance, inspections, and abseil services where roof structure or access requirements vary.
Why Use Temporary Anchors?
Temporary anchors are important in a range of scenarios where flexibility, speed, and minimal disruption are key. For instance, they are ideal when a task is short-term or infrequent, such as a one-off inspection or temporary maintenance job.
They are also the go-to solution when building owners prefer to avoid altering the property, particularly in cases involving heritage buildings or surfaces with waterproof membranes that must not be penetrated.
Temporary anchors also offer unmatched mobility, allowing teams to move between locations quickly without needing to reinstall or re-engineer access points each time.
Key advantages include:
-
Mobility: Easily repositioned as work progresses.
-
No structural impact: Perfect for older or waterproofed roofs.
-
Quick setup: Saves time and labour.
-
Cost-effective: No need for permanent fixings or structural engineering.
Types of Temporary Anchor Systems
There’s no one-size-fits-all when it comes to temporary anchors. Each system is built for specific site conditions, roof types, and fall protection needs. EN 795 is the key standard for personal fall protection anchors and classifies these systems into five categories. Temporary anchors generally fall into one of the following:
-
Type B: anchors that are temporarily fixed and can be removed without leaving a trace
-
Type E: anchors that are held in place by their own weight (e.g. deadweight anchors)
Understanding the type you're dealing with and its implications for setup, testing, and compliance is crucial for selecting the right option.
Slings, Straps, and Beam Clamps (Type B)
These are some of the most common anchors used in rope access. They wrap around beams, posts or other structural elements, offering a quick, flexible solution where fixed anchors aren’t available.
-
Must meet minimum strength ratings: typically 22 kN for synthetic slings and 15 kN for wire rope.
-
Commonly used in abseil setups or temporary rope access.
-
Only suitable where the supporting structure can take the required loads.

Tripods and Quadpods (Type B)
These are portable frames used to create overhead anchors, often for confined space entry (like manholes or septic tanks).
-
Require a flat, stable surface for safe setup.
-
Must never be used as the sole anchor for fall arrest, a secondary independent system is needed.
-
Often paired with winches or lifelines for safe entry and rescue.

Deadweight Anchors (Type E)
Deadweight systems sit on a flat roof surface and are held in place purely by their own mass and friction.
-
Ideal for flat roofs where drilling is not permitted (e.g., membrane systems).
-
Not suitable for slopes steeper than 5°.
-
Made from dense materials like concrete or steel.
-
Must be tested on the specific roof surface to ensure adequate friction.

Counterweight Anchors (Type B)
These systems use a cantilevered arm extending over a roof edge, balanced by counterweights on the other side.
-
Common for window cleaning or facade access when edge penetration isn’t allowed.
-
Most are rated for one person only, unless certified for rescue use.
-
Set up must consider overbalance risks and anchorage location.

Natural Anchors (Type B)
In rare cases, natural features like trees or rock outcrops can be used as anchors. Natural anchors should only be used in exceptional circumstances and require formal strength assessment.
-
Must be part of solid bedrock or a healthy, stable tree.
-
Require thorough visual inspection and strength assessment.
-
May also need load testing to verify suitability.

Vehicles and Mobile Plant (Type B)
Large vehicles or plant can serve as temporary anchors in some scenarios, provided strict conditions are met.
-
Must be braked, chocked, and isolated to prevent movement.
-
Friction and mass must be assessed to ensure stability.
-
Not suitable in areas with sloped terrain or soft surfaces.
This is a general overview and should not be used as the basis for risk assessments and method statements (RAMS). Any proposed arrangement requires a site-specific assessment by competent personnel, with findings and control measures documented before use. For IRATA rope access, consult ICOP Annex F, section F.3.6, and involve the responsible Level 3 supervisor in determining suitability.
Anchor Slings and Scaffold Hooks (Type B)
These are typically used on scaffold structures or wide tubes, where they wrap or connect securely to create a tie-in point.
-
Must avoid side loading and contact with sharp edges.
-
Must meet strength standards and be used as per manufacturer's guidelines.
-
Always check compatibility with the structure and fall arrest gear.

Regulations and Strength Requirements
Using the right anchor is about more than what looks right, it's a legal and safety obligation. Here are the standards that matter:
-
BS EN 795: Performance and testing for anchor devices (Types A-E).
-
PD CEN/TS 16415: Anchor standards for multiple-users.
-
BS 7883: Anchor system design, layout and inspection requirements.
-
BS EN 365: Use, maintenance and marking of PPE.
-
BS 8610: Anchor system specifications.
-
BS 8437: Practical guidance on use and maintenance.
-
BS EN 363: Overall system compatibility and function.
Compliance ensures that the anchor not only performs in a test but also functions safely in real-world conditions.
How to Choose the Right Temporary Anchor
1. Assess the Application
-
Is it for abseiling (rope access) or fall arrest?
-
Abseil anchors typically need to withstand at least a 15 kN static load.
2. Evaluate the Structure
-
Concrete, timber, steel? Each has different attachment needs.
-
If unsure, always get a sign-off from a qualified engineer.
3. Choose an Anchor Compatible with the Surface
-
For example, deadweight anchors on flat, delicate roofs.
-
Purlin mounts for metal structures.
4. Decide Between Penetrating and Non-Penetrating
-
Non-penetrating: Good for waterproof membranes.
-
Penetrating: Necessary for structural connection in some materials.
5. Position Anchors Correctly
-
Avoid swing falls.
-
Keep near safe access points like ladders.
6. Check Certification
-
Only use anchors with valid certification.
-
Follow the manufacturer's instructions and test results.

Installation and Best Practices
Correct placement of temporary anchors is essential to avoid hazards like swing falls, where a fall occurs and the worker swings sideways like a pendulum toward the anchor point, potentially hitting nearby structures. Anchors should be placed directly above the work area whenever possible to reduce this risk.
It's also vital to guarantee the load direction aligns with the device specifications and that there's sufficient fall clearance beneath the anchor point to prevent ground impact in the event of a fall.
Inspection and Maintenance
Proper inspection and maintenance are vital to ensuring temporary anchor systems remain safe and effective throughout their use. While BS EN 795 defines the strength and performance criteria for Type B anchors, the real-world reliability of any system depends on how it’s installed, used, and maintained.
Daily Pre-Use Checks
Before each use, workers must carry out a visual inspection of the entire anchorage system. This includes checking for:
-
Signs of wear, damage, or corrosion.
-
Contamination or debris that could compromise performance.
-
Missing or malfunctioning components.
These quick checks are a crucial first step and often the easiest way to spot problems before they lead to failure.

Periodic Inspections by a Competent Person
Beyond daily checks, a more thorough inspection should be conducted at regular intervals by someone qualified. The appropriate frequency will vary depending on use and conditions, but it must be carried out at least once every 12 months, reducing to every 6 months if PFPS is used for suspension (e.g. rope access, work positioning).
This deeper review should assess the condition of all components, ensure continued compliance with standards, and be documented thoroughly.
Periodic inspections will often involve pull testing, or proof load testing, depending on the examination scheme for inspection and manufacturers guidance. Proof load testing is typically not required for Type B (removable and transportable) and Type E (mass and friction-dependent) anchor devices.

Certification and Recordkeeping
Every anchor system used on site must:
-
Comply with applicable standards such as BS EN 795 and BS 7883.
-
Be certified for the required load.
-
Have a log of inspection records, including dates, outcomes, and inspector names.
Keeping this documentation up to date not only ensures compliance but also provides essential traceability in the event of a safety review or incident.
Responding to Damage or Defects
If any part of the system is found to be damaged or suspect:
-
Take it out of service immediately.
-
Consult the manufacturer for guidance on repair, replacement or disposal.
Even small issues can undermine the integrity of the system, so it’s never worth taking a risk.
Common Mistakes to Avoid
-
Using uncertified or makeshift anchors.
-
Incorrect sling angles increase load stress.
-
Lack of edge protection.
-
Misjudging surface friction for deadweight systems.
-
Failing to isolate vehicles used as anchors.
Need Help Choosing or Installing Temporary Anchors?
Temporary anchor systems are an important part of modern fall protection. Whether you’re planning work at height, reviewing your current safety systems, or unsure which anchor to use for a unique roof structure, it’s essential to get expert advice.
At Spectrum, we help ensure that your building remains safe and compliant. We work with temporary and permanent anchorage every day, providing an extensive range of maintenance services.
If you need help making sense of it all, contact us today to speak with a fall protection expert. Or, learn more about our fall protection services here.
Your Building Deserves Thoughtful, Expert Care
Ensure your building remains in top condition with Spectrum Specialist Support. Our expert team offers a full range of exterior maintenance services, from external cleaning and repairs to comprehensive restoration of brick, render, stone and other substrates.
With an IRATA-certified team of abseilers and experience across hundreds of varied projects, we’ll find an access solution that saves you time and money, even on the most complex elevations.
Whether you need emergency maintenance or a tailored service plan, we are here to help. Contact us directly on 020 3551 6206 or email us at info@spectrumss.co.uk to discuss your requirements and receive a free consultation and quote.